Permit Info
Short Description:
3672 AC, 4416 SF, SFR / 2 STORY
Approved Date:
11/14/2017
Expiration Date:
9/25/2018
Notes:
11/14/2017 3:11:01 PM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
013. BEAMS=10"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
**** 2ND STORY - GR, M, 3BR & 2BA ****
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
LEXINGTON PHASE ONE (CFR)
|
APPLICANT | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | 4050 W Park Blvd | PLANO, TX 75093 |
OWNER | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | 4050 W Park Blvd | PLANO, TX 75093 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8338 | aschmiat@lsmech.com | | RICHARDSON, TX 75081 |
|
SEWER IMPACT FEE |
$1,619.00
|
|
THOROUGHFARE IMPACT FEE |
$0.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
RESIDENTIAL FEE (E) |
$132.48
|
|
MISCELLANOUS MECHANICAL FEES |
$139.50
|
|
MISCELLANEOUS PLUMBING FEES |
$256.00
|
|
FENCE FEE |
$20.00
|
|
BUILDING PERMIT FEE |
$1,753.75
|
|
Total Fees |
Charged: $5,692.73
Balance Due: $5,692.73
|
There are currently no inspections on this record.
|
INITIAL REVIEW | DEMETRI JOHNSON | | 10/27/2017 | | |
More Info
|
RESIDENTIAL REVIEW | CAREY L FRAZIER | APPROVED AS NOTED | 11/14/2017 | 11/14/2017 | |
More Info
|