Notes:
A- CONTINGENT UPON COMPLIANCE WITH P+Z & CIVIL ENGG APPROVALS OF SITE PLAN, BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
B-DELETE
C- ALL PARTS OF THE BLDG ENVELOPE MUST MATCH OR EXCEED THE MIN. INSULATION REQUIREMENTS OF IECC, WITH R-11 FOR WALLS, R-20 FOR ROOF.
D- STOREFRONT GLAZING TO BE 1" INSULATED GLASS TO PROVIDE MAX. SHGC=0.6 AND MAX. U=0.7. (MUST CONFORM WITH SAFETY GLASS REGULATIONS. ALSO ANY FUTURE RATED WALL ENDING AT THE STOREFRONT MUST PROVIDE 1 HR FIRE/SMOKE CONNECTION TO THE NEAREST MULLION OR PILASTER).
E- SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
1. ALL WORK SUBJECT TO FIRE MARSHAL/CITY APPROVED INSPECTIONS AND TESTING.
2. FULLY SPRINKLED.
3. INTERIOR FINISHES: GROUP A, CLASS B, FLAME SPREAD 26-75
SMOKE DEVELOPED 0-450.
1973 SQ FT, CALT / DICK'S SPORTING GOODS (81726 T.U.R.)