Notes:
5016 SQ FT, CALT / JC PENNEY (AMERICAN LIVING)
10/24/2007 12:00:00 AM
5016 SQ.FT. DEMO/REMODEL DISPLAY AREAS AND DRESSING ROOMS
1. ALL WORK SHALL COMPLY WITH CURRENT I-CODES.
2. ANY POKE THRU ELECTRICAL DEVICES SHALL BE FIRE/SMOKE UL RATED.
3. ALL WORK SUBJECT TO FIRE MARSHAL/CITY APPROVED INSPECTIONS AND TESTING.
4. INTERIOR FINISHES:
GROUP A, CLASS B, FLAME SPREAD 26-75, SMOKE DEV. 0-450.
5. ALL WOOD USED AS A STRUCTURAL COMPONENT OR BLOCKING SHALL BE FRT WOOD.
001. MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS.
002. NO ALUMINIM WIRE PERMITTED--1/0 SERVICE CONDUCTORS ONLY USING STABIL-ALLOY SERIES 6000 & 8000.
003. PULL EQUIPMENT GROUNDS IN ALL RACEWAYS.
004. PROVIDE EXIT AND EMERGENCY LIGHTING AS NOTED AND REQUIRED PER 20003 IBC.
005. LIGHTING AND CONTROLS SHALL COMPLY WITH 2000 IECC WHERE APPLICABLE.
006. ALL ELECTRICAL INSTALLATIONS WILL BE SUBJECT TO FIELD INSPECTIONS AND INSPECTOR APPROVALS.
007. ELECTRICAL WILL BE DESIGNED AND INSTALLED PER THE 1999 NATIONAL ELECTRICAL CODE WITH LOCAL AMENDMENTS STATED IN CITY OF FRISCO ORDINANCE 00-03-02 ALONG WITH THE FOLLOWING COMMENTS.
DUCT WORK ONLY--MECHANICAL. NO CHANGE TO HVAC UNITS