Notes:
1312 SQ FT, CIFO / ILLUMINATIONS
6/29/2007 12:00:00 AM
1. fully sprinkled.
2. all work subject to approved city inspections and/or testing.
3. interior finishes: flame spread 76-200 smoke developed 0-450
4. any wood used in construction shall be fire treated.
5. maintain 1 hr. UL-U465 demising wall separation @ bulkhead enclosure.
6. transformer cannot extend into req'd. work area more than 6" ( this is under electr. EMSP panel.
7. follow notations & comply with ADA & TAS assessment review (TDLR Arch. Barrier form) which is attached to permit copy.
8. tempered glass where applicable.
9. pull/front approach 18" req'd. manuevering clearance @ mop sink.
10. 7' clearance @ hallway to restroom---3' door plus 4' from edge of door to adjacent wall.
11. all poke thru electrical devices shall be UL rated fire proof.