Permit Info
Short Description:
*EXPIRED*2916 SQ FT, CIFO / COACH
Approved Date:
11/28/2006
Expiration Date:
3/6/2008
Notes:
*EXPIRED*2916 SQ FT, CIFO / COACH
11/14/2006 12:00:00 AM
PLAN REVIEW COMMENTS;
1. THE STOCKROOM IS AN INCIDENTAL USE FOR THE MAIN OCCUPANCY OF RETAIL AND SHALL THEREFORE BE SEPARATED BY AT LEAST 1-HOUR FIRE BARRIER WALL OR SMOKE BARRIER WALL, SO THE WALL IN BETWEEN THE STOCKROOM AND RETAIL SHALL HAVE 1-HOUR FIRE BARIER FROM FLOOR TO DECK ABOVE. ALL DOOR OPENING SHALL HAVE AUTOMATIC CLOSER OR SELF CLOSING.
2. SAFETY GLAZING REQUIRED.
3. THE SECOND MEANS OF EGRESS GOING INTO THE STOCKROOM IS NOT ALLOWED BUT IF THE PATH OF TRAVEL WILL BE STRIPED AND PAINTED AND NO STORAGE AT ALL TIMES WE CAN ALLOW IT.
4. ONE OF THE LAST SHELF NEAR THE SECOND MEANS OF EGRESS SHALL BE MOVED INORDER TO COMPLY WITH ADA MANEUVERING REQUIREMENTS (48" X 48").
5. ANY WOOD USED IN A TYPE II-B NONCOMBUSTIBLE SHALL BE FIRE RETARDANT WOOD.
6. WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD RATING OF 76-200; SMOKED DEVELOPED INDEX OF 0-450.
7. FIRE/SMOKE DAMPERS REQUIRED IN ALL PENETRATION OF 1-HOUR FIRE BARRIER/SMOKE BARRIER WALL.
8. SUBJECT TOFIELD INSPECTION AND TESTING.
(3/6/2008 12:01 MBW)
EXPIRED PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONEBRIAR MALL AT THE BRIDGES
|
APPLICANT | SCOTT DAVES | (626)585-2931 | | 140 S. LAKE AVE #323 | PASADENA, CA 91101 |
OWNER | MALL STONEBRIAR | ()- | | 110 WACKER DR N | CHICAGO, IL 60606-1511 |
CONTRACTOR | TBD | ()- | | | |
MECH. CTR. | TBD | ()- | | | |
GEN. CONTR. | TBD | ()- | | | |
|
MISCELLANOUS MECHANICAL FEES |
$41.30
|
|
MISCELLANEOUS PLUMBING FEES |
$60.00
|
|
COMMERCIAL ELECTRIC FEE |
$136.24
|
|
COMMERCIAL BUILDING PERMIT FEE |
$746.25
|
|
Total Fees |
Charged: $983.79
Balance Due: $983.79
|
There are currently no inspections on this record.
|
COMMERCIAL REVIEW | PPB | Approved as Noted | 11/9/2006 | 11/14/2006 | |
More Info
|
ELECTRICAL REVIEW | GLQ | Approved | 11/9/2006 | 11/15/2006 | |
More Info
|
INITIAL REVIEW | MBW | Pending | 11/9/2006 | 11/9/2006 | |
More Info
|
MECHNICAL REVIEW | PPB | Approved as Noted | 11/9/2006 | 11/14/2006 | |
More Info
|
PLUMBING REVIEW | PPB | Approved as Noted | 11/9/2006 | 11/14/2006 | |
More Info
|
MISC REVIEW | Michele Wood | CALLED STORE | 3/6/2008 | 3/6/2008 | |
More Info
|