3005 SQ FT, CIFO / SOMA
8/31/2006 12:00:00 AM
1. Revised plans were submitted.
(8/10/2006 14:37 PPB)
Plan review comments;
1. Portion of service/customer counter surface shall be 38" maximum high above finish floor.
2. Mop/service sink required.
3. Door 2A shall have self closing or automatic closer.
4. Floors and walls shall have smooth, hard and non-absorbent surface.
5. Penetrations on demising walls shall not reduced its 1-hour fire resistive construction.
6. The energy compliance report specify 131 lighting fixtures are to be installed while the construction drawings has more than this numbers and also the mechanical report doesn't show the equipment type, size and efficiency. The city of Frisco under 2003 IECC.
7. Flame spread requirements of interior finish-out shall comply with Table 803.5.
8. Smoke damper required on penetration of fire rated assembly.