Permit Info
Short Description:
*EXPIRED*3298 SQ FT, CIFO / CADILLAC CANTINA
Expiration Date:
3/12/2006
Notes:
*EXPIRED*3298 SQ FT, CIFO / CADILLAC CANTINA
8/20/2005 12:00:00 AM
1. 1 hour fire/smoke connection to mullion.
2. 1 hour fire/smoke construction w/ 3 5/8” metal studs w/ 5/8” type X gypsum on both sides up to deck and fire caulked @ demising wall.
3. 2 hour ceiling construction.
4. tempered windows where door is 2' from window.
5. maintain 44" egress at rear entry.
(9/2/2005 11:02 JS) (9/2/2005 10:59 JS)(8/30/2005 16:06 JS)
PLEASE COMPLY WITH HEALTH ORDINANCE # 00-03-19 AND SMOKING ORDINANCE #00-12-12.
(8/30/2005 16:06 JS)
ALL BASE NOTED IN AREAS 110, 108,109,107,104 AND THE WALK IN COOLER REQUIRE INTEGRAL COVED TILE BASE. BAR AND BUS STATION WALLS ARE REQUIRED TO BE NON-POROUS, EASILY CLEANABLE. (FRP TYPICAL). KITCHEN CEILING IS REQUIRED TO HAVE A NON-POROUS, EASILY CLEANABLE SURFACE. FLOOR MOUNTED MOP SINK IS REQUIRED. GREASE INTERCEPTOR SIZING CLARIFICATION REQUIRED.
(9/9/2005 11:24 JS)
TENANT TO TIE INTO EXISTING GREASE WASTE LINE SHARED BY BEST THAI. LETTER ON FILE REGARDING SEPARATE GREASE WASTE LINES AND INTERCEPTORS FOR FUTURE FOOD ESTABLISHMENTS.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
FRISCO SQUARE #02
|
APPLICANT | CADILLAC CANTINA | (972)896-3036 | cadillaccantina@hotmail.com | 8801 COLEMAN BLVD | FRISCO, TX 75034 |
OWNER | FRISCO SQUARE LTD | (469)633-1721 | | 8940 JOHN ELLIOTT DR | FRISCO, TX 75034 |
CONTRACTOR | LI DESIGN ASSOC-NOT REGISTERED | ()- | | | |
ELECT. CTR. | M & S ELECTRIC | (972)516-8876 | | PO BOX 310 | LAVON, TX 75166 |
MECH. CTR. | SUMNERS HEATING & AIR X-3/2006 | (972)557-1507 | | 3215 S PEACHTREE RD. | MESQUITE, TX 75180 |
GEN. CONTR. | LI DESIGN ASSOC-NOT REGISTERED | ()- | | | |
PLUM. CONT. | REEVES PLUMBING SYSTEMS | (972)329-0600 | | 1426 HIGHLAND | MESQUITE, TX 75149 |
|
MISCELLANOUS MECHANICAL FEES |
$143.00
|
|
MISCELLANEOUS PLUMBING FEES |
$222.00
|
|
BUILDING PERMIT FEE |
$1,368.75
|
|
COMMERCIAL ELECTRIC FEE |
$151.92
|
|
Total Fees |
Charged: $1,885.67
Balance Due: $1,885.67
|
There are currently no inspections on this record.
|
COMMERCIAL REVIEW | Jeff Maxwell | Appd w/ Cond | 8/12/2005 | 8/20/2005 | |
More Info
|
ELECTRICAL REVIEW | Ginny Queen | Approved | 8/12/2005 | 8/18/2005 | |
More Info
|
INITIAL REVIEW | Michele Wood | Pending | 8/12/2005 | 8/12/2005 | |
More Info
|
MECHNICAL REVIEW | Tom Wheeler | Appd w/ Cond | 8/12/2005 | 8/25/2005 | |
More Info
|
PLUMBING REVIEW | Gilbert Urvina | Approved | 8/12/2005 | 8/24/2005 | |
More Info
|
HEALTH REVIEW | Julie Stallcup | Appd w/ Cond | 8/25/2005 | 8/30/2005 | 9/15/2005 |
More Info
|
HEALTH REVIEW | Julie Stallcup | Appd w/ Cond | 9/2/2005 | 9/2/2005 | 9/9/2005 |
More Info
|
MISC REVIEW | Carey L Frazier | Pending | 9/12/2005 | 9/12/2005 | 9/12/2005 |